Chaparral G5312/G7313 Manual Do Utilizador

Página de 160
G- and K-Series User’s Guide
 
9-8
Errors
Error events let you know that something related the enclosure, controller, or disk 
drives has failed and requires immediate attention. Table 9-2 defines each error event 
and recommends the action you should take.
ARRAY OFFLINE
More than one drive in a RAID 
0 or volume set went down 
bringing the array to an offline 
state. This array is no longer 
accessible by the host.
Replace the bad drive and restore 
the data from backup.
VOLT/TEMP 
WARN
The analog to digital convertor 
monitored a temperature and/or 
voltage in the warning range. 
Check that the controller’s fan is 
running. Check that the ambient 
temperature is not too warm. See 
Specifications on page 1-7.
UNWRITABLE 
CACHE
The SDRAM cache has battery 
backed up data, and the arrays 
assigned to this data are not 
present. 
Either determine which drives are 
missing and reinstall them, or 
select Yes when asked if you want 
to discard this data.
SDRAM CORR 
ECC
A correctable single bit 
SDRAM ECC error.
If this error occurs frequently, 
replace the memory.
Table 9-2. Error events
Event
Definition
Recommended Action
VOLT/TEMP 
FAIL
The analog to digital 
convertor
 monitored a 
temperature and/or voltage in the 
failure range
.
Check that the controller’s fan is 
running. Check that the ambient 
temperature is not too warm. See 
Specifications on page 1-7.
ENCLOSURE 
FAIL
Enclosure-specific general 
purpose IO trigger a failure 
condition.
Check the status of the enclosure. 
Refer to the enclosure’s 
documentation.
BATTERY 
FAILED
A failure in the battery pack 
and/or charging interface has 
been detected.
Replace the controller’s battery.
Table 9-1. Warning events (Continued)
Event
Definition
Recommended Action