Server /chassis/storageadapter #
scope physical-drive 3
Server /chassis/storageadapter/physical-drive #
make-dedicated-hot-spare
5: VD_OS_1, RAID 0, 102400 MB, physical disks: 1
6: VD_OS_2, RAID 0, 12288 MB, physical disks: 1
7: VD_OS_3, RAID 0, 12288 MB, physical disks: 1
8: VD_DATA_1, RAID 0, 12512 MB, physical disks: 1
9: RAID1_2358, RAID 1, 40000 MB, physical disks: 2,3,5,8
11: JFB_RAID1_67, RAID 1, 20000 MB, physical disks: 6,7
12: JFB_Crv_R1_40, RAID 1, 40000 MB, physical disks: 6,7
13: JFB_R1_10GB, RAID 1, 10000 MB, physical disks: 6,7
Please choose from the above 8 virtual drives-->
6
Server /chassis/storageadapter/physical-drive #
Making a Global Hot Spare
Before You Begin
You must log in with admin privileges to perform this task.
Procedure
Purpose
Command or Action
Enters the chassis command mode.
Server# scope chassis
Step 1
Enters command mode for an installed
storage card.
Server /chassis # scope storageadapter slot
Step 2
Enters command mode for the specified
physical drive.
Server /chassis/storageadapter # scope
physical-drive 
drive-number
Step 3
Server /chassis/storageadapter/physical-drive #
make-global-hot-spare
Step 4
Displays the status of the task that is in
progress on the drive.
Server /chassis/storageadapter/physical-drive #
get-operation-status
Step 5
This example shows how to make physical drive 3 a global hot spare:
Server#
scope chassis
Server /chassis #
scope storageadapter SLOT-3
Server /chassis/storageadapter #
scope physical-drive 3
Server /chassis/storageadapter/physical-drive #
make-global-hot-spare
Server /chassis/storageadapter/physical-drive #
Preparing a Drive for Removal
You can confirm this task only on physical drives that display the Unconfigured Good status.
Before You Begin
You must log in with admin privileges to perform this task.
   Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5
122
OL-28893-01  
Managing Network Adapters
Making a Global Hot Spare