Server /cimc #
scope firmware
Server /cimc/firmware #
show detail
Firmware Image Information:
Update Stage: NONE
Update Progress: 100
Current FW Version: 1.4(3j)
FW Image 1 Version: 1.4(3j)
FW Image 1 State: RUNNING ACTIVATED
FW Image 2 Version: 1.3(3a)
FW Image 2 State: BACKUP INACTIVATED
Boot-loader Version: 1.4(3.21).18
Installing BIOS Firmware from a Remote Server
This procedure is not available on some servers. For other BIOS installation methods, see the Cisco UCS
C-Series Rack-Mount Server BIOS Upgrade Guide 
available at the following URL:
Note
Before You Begin
• Log in to the as a user with admin privileges.
• Activate the CIMC firmware that goes with the BIOS version you want to install, as described in .
• Power off the server.
If you start an update while an update is already in process, both updates will fail.
Note
Procedure
Purpose
Command or Action
Enters the CIMC command mode.
Server# scope cimc
Step 1
Enters the firmware command mode.
Server /cimc # scope firmware
Step 2
Displays the available firmware images and status.
Server /cimc/firmware # show detail
Step 3
If the CIMC firmware version does not
match, activate the CIMC firmware
before continuing with this procedure
or the server will not boot. For details,
see
Firmware, on page 160
.
Important
Make sure the firmware version shown
in the Current FW Version field
matches the BIOS firmware version you
are installing.
Step 4
Returns to the server root level.
Server /cimc/firmware # top
Step 5
Enters the BIOS command mode.
Server# scope bios
Step 6
   Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5
162
OL-28893-01  
CIMC Firmware Management
Installing BIOS Firmware from a Remote Server