Cisco Systems 57712 Manual Do Utilizador

Página de 288
Server Management BIOS Parameters for C260 Servers
Description
Name
Whether the BIOS generates a non-maskable interrupt (NMI)
and logs an error when a system error (SERR) occurs. This can
be one of the following:
• Disabled—The BIOS does not generate an NMI or log an
error when a SERR occurs.
• Enabled—The BIOS generates an NMI and logs an error
when a SERR occurs. You must enable this setting if you
want to enable .
Assert NMI on SERR
Whether the BIOS generates a non-maskable interrupt (NMI)
and logs an error when a processor bus parity error (PERR)
occurs. This can be one of the following:
• Disabled—The BIOS does not generate an NMI or log an
error when a PERR occurs.
• Enabled—The BIOS generates an NMI and logs an error
when a PERR occurs. You must enable to use this setting.
Assert NMI on PERR
Allows a serial port to be used for console redirection during
POST and BIOS booting. After the BIOS has booted and the
operating system is responsible for the server, console redirection
is irrelevant and has no effect. This can be one of the following:
• Disabled—No console redirection occurs during POST.
• —Enables console redirection on serial port A during
POST.
If you enable this option, you also disable the display
of the Quiet Boot logo screen during POST.
Note
Console Redirection
Whether a handshake protocol is used for flow control. Request
to Send / Clear to Send (RTS/CTS) helps to reduce frame
collisions that can be introduced by a hidden terminal problem.
This can be one of the following:
• None—No flow control is used.
• RTS-CTS—RTS/CTS is used for flow control.
This setting must match the setting on the remote
terminal application.
Note
Flow Control
   Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5
232
OL-28893-01  
BIOS Parameters by Server Model
Server Management BIOS Parameters for C260 Servers