Description
Name
The action the system should take if power capping is enabled and the
server requests more than its peak power allotment. This can be one of
the following:
• —The server is forced to reduce its power consumption by any
means necessary. This option is available only on some C-Series
servers.
• —No action is taken and the server is allowed to use more power
than specified in the Peak Power field.
• —The server is shut down.
• —Processes running on the server are throttled to bring the total
power consumption down.
Non-Compliance Action
This example displays the detailed power statistics:
Server#
show power-cap detail
Cur Consumption (W): 247
Max Consumption (W): 286
Min Consumption (W): 229
Minimum Configurable Limit (W): 285
Maximum Configurable Limit (W): 1250
Power Cap Enabled: yes
Peak Power: 0
Non Compliance Action: throttle
Server#
Power Capping Policy
The power capping policy determines how server power consumption is actively managed. When power
capping is enabled, the system monitors how much power is allocated to the server and attempts to keep the
power consumption below the allocated power. If the server exceeds its maximum allotment, the power
capping policy triggers the specified non-compliance action.