Appendix A.  Principles of Operation 
A.1  Data Collection 
The SDM-CAN operation is based on a number of sequential buffers. The 
hardware has a dedicated CAN controller chip connected to a microprocessor 
which analyses and processes the raw CAN data and then transmits it to the 
datalogger.  
When the CAN-Bus controller receives a good frame first of all it uses its internal 
hardware to filter out the frames of no interest to the user. If the frame ID satisfies 
the filter requirements then it allows the frame to be transferred to a hardware 
FIFO. This FIFO can hold up to 3 CAN frames. Whenever data is in this FIFO an 
interrupt mechanism will cause the SDM-CAN processor to read the data from the 
CAN controller. 
When the processor reads the CAN frame it will do a more detailed check to see if 
the CAN frame ID is one of the ones required. This is because the hardware filter 
only matches an overall pattern and may let some CAN frames through that are 
not required. If the CAN frame ID is accepted, it will then be placed into the 
‘Working Buffer’ of a ‘Buffer Set’, which is made up of a set of small buffers in 
memory, each set being dedicated to a specific packet ID. 
The ‘Buffer Set’ consist of ‘some configuration data’, ‘ID Buffer’, ‘Working 
Buffer’ and a ‘Read Buffer’. When the datalogger program is compiled it will 
configure the buffers with a specific ID in the ‘ID Buffer’ and also set up the 
buffer configuration. Many SDM-CAN instructions may share buffers because the 
CAN frame ID and configuration is the same. 
Each SDM-CAN instruction will create what is called a BIN within the SDM-
CAN. This BIN holds information such as which ‘data type’ to use, which ‘Buffer 
Set’ it should get the data from and where its ‘New data flag’ is located plus a 
large amount of other information. 
The ‘New data’ flags are set when new data arrives into the ‘Working Buffer’ of 
the ‘Buffer Set’. Because there could be multiple BINs using one ‘Buffer Set’ 
there will be multiple ‘New data’ flags as well, so all the relevant ‘New data’ flags 
will be set at the same time. When the datalogger program reaches a point where it 
needs to read the data, the SDM-CAN will first check the ‘New data flag’. If this 
flag is clear, the datalogger will read the previous data value unless the switch is 
set to detect/prevent multiple reads (see section 3) in which case an over-range 
value is read (-99999 on some dataloggers). The SDM-CAN will then clear the 
appropriate ‘New data’ flag relevant to the BIN and instruction that requested the 
data. Because there is effectively one ‘New data’ flag per call of P118 this means 
that you could read the same new data to many different locations. However, you 
should be aware that different data could be returned by the different calls of the 
instruction, as a new data frame could be captured as the datalogger works through 
the program table. This problem can be avoided by using the Global trigger 
function.  
A.2  Frame Transmission 
When the datalogger program is first run it will set-up the SDM-CAN BINs and 
buffers. If the program has some P118 instructions that transmit to the CAN-Bus, 
then some of the Buffers will be set-up for transmission. When an instruction 
indicates that a transmission should take place, the datalogger first sends a BIN 
number. This number tells the SDM-CAN which BIN to use and, from the 
compile-time set up, what operation is required. In the case of transmission it 
would expect frame data to be sent from the datalogger.  
A-1