OWNER'S MANUAL
 
Q&a
installation/access
Q
 
Why doesn’t the setting page appear in my web browser?
A
 Following causes are possible. Please check them.
 
1. The monitor does not connect to the network.
 
Check LED indicators status (
 
p.17).
 
-  Check the connection of LAN cable if the LINK indicator does not illuminate 
red.
 
-  Check the network configuration of the monitor if ACT indicator does not 
illuminate green.
 
2. Wrong network configuration of the monitor
 
 Check the network configuration of the monitor (
 
p.37).
 
3. Wrong network configuration of the computer.
 
 Check the network configuration of the computer.
 
4. The network unit is used with the default setting (
 
p.21).
 
5. The proxy setting of the web browser is not set correctly (
 
p.100).
 
6. The computer does not provide TCP/IP protocol.
Q
  No setting page in my web browser? Is the problem in the network or in 
the monitor?  I would like to find out the problem whether it is in the net-
work or in the monitor
A
 Check it by the following steps
 
1.  Disconnect the monitor from the network and connect the monitor and com-
puter with the UTP cross cable directly.
 
2.  Change network configuration of the computer and monitor as shown in the 
example below.
(Monitor setting)
IP Address 
: 192.168.0.2
Subnet Mask 
: 255.255.255.0
Default gateway 
: 0.0.0.0
DNS 
: 0.0.0.0
(Computer setting)
IP Address 
: 192.168.0.5
Subnet Mask 
: 255.255.255.0
Default gateway 
: (blank)
DNS 
: (blank)