Seagate ST3200826SCE Manual Do Utilizador

Página de 44
12
DB35 Serial ATA Product Manual, Rev. E
2.11
Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in 
performance when subjected to the radio frequency (RF) environments defined in the following table:
2.12
Reliability
Table 4: 
Radio frequency environments
Test
Description
Performance
 
level
Reference
 
standard
Electrostatic discharge
Contact, HCP, VCP: ± 4
 
kV; Air:
 
± 8 kV
B
EN 61000-4-2: 95
Radiated RF immunity
80 to 1,000 MHz, 3 V/m, 
 
80% AM with 1 kHz sine
 
900 MHz, 3 V/m, 50% pulse 
modulation @ 200 Hz
A
EN 61000-4-3: 96
 
ENV 50204: 95
Electrical fast transient
± 1 kV on AC mains, ± 0.5 kV on 
external I/O
B
EN 61000-4-4: 95
Surge immunity
± 1 kV differential, ± 2 kV com-
mon, AC mains
B
EN 61000-4-5: 95
Conducted RF immunity
150 kHz to 80 MHz, 3 Vrms, 
80% AM with 1 kHz sine
A
EN 61000-4-6: 97
Voltage dips, interrupts
0% open, 5 seconds
 
0% short, 5 seconds
 
40%, 0.10 seconds
 
70%, 0.01 seconds
C
 
C
 
C
 
B
EN 61000-4-11: 94
Nonrecoverable read errors
1 per 10
14
 bits read, max
Annualized Failure Rate (AFR)
0.34% (nominal power, 25°C ambient temperature)
Contact start-stop cycles
50,000 cycles
 
(at nominal voltage and temperature, with 60 cycles per hour and a 50% duty cycle)
Service Life
5 Years
Preventive maintenance
None required