Panduit PN433 Manual Do Utilizador

Página de 4
 
INSTALLATION INSTRUCTIONS PN433 
 
*MTP is a registered trademark of US Conec Ltd. 
 
For Technical Support:  www.panduit.com/resources/install_maintain.asp 
 
Page 2 of 4
 
SAFETY PRECAUTIONS 
1.  LASER LIGHT PROTECTION 
WARNING:  LASER LIGHT IS INVISIBLE. THE INVISIBLE LIGHT 
IS POWERFUL ENOUGH TO DAMAGE YOUR EYES. SERIOUS 
DAMAGE TO THE RETINA OF THE EYE IS POSSIBLE. NEVER 
LOOK INTO THE END OF A FIBER THAT MAY HAVE A LASER 
COUPLED INTO IT. SHOULD ACCIDENTAL EYE EXPOSURE TO 
LASER LIGHT BE SUSPECTED, ARRANGE FOR AN EYE 
EXAMINATION IMMEDIATELY.
 
 
2. CABLE HANDLING 
WARNING:  FIBER OPTIC CABLE CAN BE DAMAGED BY 
EXCESSIVE PULLING, TWISTING, CRUSHING OR BENDING 
STRESSES.  CONSULT THE APPROPRIATE SPECIFICATION 
SHEETS AS PROVIDED BY YOUR CABLE VENDOR.  ANY 
DAMAGE MAY DECREASE OPTICAL PERFORMANCE.
  
 
 
 
Important Connector Cleaning Information 
Clean all connectors prior to connection.  Just like single fiber connectors, all multi-fiber connectors must be properly cleaned 
prior to connection to ensure optimum optical performance is achieved. Although interconnect cords and cable assemblies are 
shipped from the factory pre-cleaned and protected with a dust cover, the user should never assume the ferrule or connector 
has not been contaminated. A contaminated endface may not meet system insertion loss and reflectance requirements or may 
cause permanent damage to the fiber(s) when mated to another connector.  Therefore, it is recommended that each ferrule 
endface or tip be cleaned using this procedure prior to connection. 
FMTPFCT Instructions - Cleaning Female MTP* Connectors 
1.  Grip the FMTPFCT, depressing the green lever of the 
cleaning tool. The metal shutter on top of the cleaning tool 
will open, exposing fresh cleaning material.  Fresh material 
is exposed each time the green lever is depressed. 
2.  Position the female MTP* ferrule endface so that the fiber 
tips are in contact with the cleaning material. Wipe the 
ferrule endface along the cleaning material in the direction 
shown on the cleaning tool. 
3.  Release the green lever of the cassette to cover the 
cleaning material. 
4.  Repeat steps 1, 2 and 3 to ensure that any contamination 
is removed.