Chapter 3: AT Commands Reference
April 15, 2008
G24-L AT Commands Reference Manual
3-129
Hardware Information
Hardware Information Commands
+CBC, Battery Charger Connection
This command enables a user to query the battery charger connection. The battery level is an
avarage value, which is updated every 30 seconds
avarage value, which is updated every 30 seconds
The following table shows the +CBC parameters.
Note:
The G24-L does not allow the detection of battery use. The power supply of the G24-L is
connected via the battery pins. However, users can use this command to verify the level
of the G24-L input power source.
connected via the battery pins. However, users can use this command to verify the level
of the G24-L input power source.
Example
AT+CBC
+CBC: 0,60
//This example shows 0 (battery powered) with 60% power.
Command Type
Syntax
Response/Action
Read
+CBC
+CBC:<bcs>,<bcl>
Table 3-81: +CBC Parameters
<Parameter>
Description
<bcs>
Charger detection
0
0
Charger not detected
1
Charger detected
Note:
The G24-L input power source is connected via the battery
pins.
pins.
<bcl>
Battery charge level:
VCC, V
Battery Level
>3.7
90%
3.5-3.7
60%
3.4-3.5
20%
3.35-3.4
10%
3.3-3.35
5%
<3.3
0%