Configuration Aspects for Programmers
Appendix C
C-16
NetScan User’s Manual
With Alarm Stamping:
PRINT#1, “A#1X”
‘ Enable alarm stamping
‘ Configure and start an acquisition
PRINT#1, “R1X”
  
‘ Request the next scan in the buffer
LINE INPUT#1, A$
‘ Retrieve it
PRINT A$
....+0234.20-0019.40+0001.40+0023.60 005 128 032 066
Digital Input Stamping (
I#
)
Digital Input Stamping (
I#
) allows you to see whether a digital input was “active” or “inactive” at the time of
the scan.  This is accomplished by a digital input “ON” (1) or “OFF” (0) code appended to the scan in real time.
Digital Input Stamping can be enabled with the 
I#1
 
command and disabled with the 
I#0
 command. Note that
there are 8 digital inputs.
Note:
Digital Input Stamping is not valid in high-speed, single channel mode (burst mode).
Examples of  
I#
 command follow.
Without Digital Input Stamping (default):
PRINT#1, “I#0X”
‘ Disable digital input stamping
‘ Configure and start an acquisition
PRINT#1, “R1X”
  
‘ Request the next scan in the buffer
LINE INPUT#1, A$
‘ Retrieve it
PRINT A$
....+0234.20-0019.40+0001.40+0023.60