Nokia 12 GSM MODULE REMOTE I/O Manual Do Utilizador

Página de 53
 
Table 6. Commands for the password control. 
Command Type 
Command 
Comments 
Changing Password 
term123 passWORD 
Change_PWord wordPASS 
OK Response:  
CHANGE_PWORD wordPASS: OK 
Fail Response:  
CHANGE_PWORD: FAILED 
The example 
changes the 
password from 
‘passWORD’ to 
‘wordPASS’ 
Activating Password 
Property 
term123 Change_PWord 
wordPASS 
OK Response:  
CHANGE_PWORD wordPASS: OK 
Fail Response:  
CHANGE_PWORD: FAILED 
The example 
changes an empty 
password to 
‘wordPASS’ 
Deactivating 
Password Property 
term123 wordPASS 
Change_PWord 
OK Response:  
CHANGE_PWORD: OK 
Fail Response:  
CHANGE_PWORD: FAILED 
The example 
changes the 
password from 
‘wordPASS’ to an 
empty password 
 
 
Note: An indication of a password change is only sent to the phone number where 
the change was requested. 
9.3.2 Reading 
Inputs 
Use the Input_Get X commands for reading inputs, that is the state or value of 
a device. Note that all example control messages in this chapter use the 
“term123” identifier string and the password property is set off (see Table 7) 
A response depends on the pin. There are three analog inputs (1-3) and nine 
digital inputs (4-11) in the Nokia 12 GSM Module M2M system interface. You 
can also specify an alias for the response (see chapter 9.2).  
 
 
30/49