Chapter 2 Cabling the VPN Router and turning the power on
NN46110-318 02.01
The power cord must meet the requirements described in
To connect the power cord and turn on the system power:
1
Connect the power cord to the AC receptacle on the back of the gateway (see
).
2
Connect the power cord to the power outlet.
3
Press and release the power switch on the rear of the VPN Router 2750
(
(
), and wait for the gateway to boot.
Table 3
Power cord requirements
Requirement
Description
Current rating
The power cord must be rated for the available AC voltage
and must have a current rating that is at least 125 percent of
the gateway’s current rating (5 A @ 100 VAC or 3 A @ 240
VAC).
Certification
The power cord must have certification marks from an
acceptable regional agency.
Cord length and flexibility The power cord must be less than 4.5 meters (14.7 feet) long.
It must be a flexible HAR (harmonized) cord or VDE-certified
cordage to comply with the gateway’s safety certifications.
Power supply connector
The connector that you plug into the AC receptacle on the
gateway must be an IEC 320, Sheet C13 female.
Wall outlet connector
The power cord must terminate in a male plug with
appropriate grounding.
Caution:
Risk of equipment damage
Protect the VPN Router 2750 by plugging it into a surge suppressor.