Installation procedures
67
and
on
, and
.
2
Connect an NE-A25B cable to each connector associated with a
card slot containing a SILC or UILC circuit card. See
and
on
and
and
on
.
Tag both ends of each cable with the cabinet or MG 1000S connector
numbers.
3
Connect the cables to the connectors at the bottom of the cabinet
or at the rear of the MG 1000S.
4
Replace the retaining bar when you connect all the cables to the
system.
5
Terminate the 25-pair cables at the cross-connect terminal.
6
Label the cross-connect terminal for each connector (UILC or SILC).
and
on
show the
label used with the BIX cross-connecting system.
Note: Use of the BIX cross-connect system is not mandatory.
The system supports other cross-connect equipment. Refer to
the documentation provided with your cross-connect system for
further information.
—End—