Nortel Networks 893-862-B Manual Do Utilizador

Página de 12
 
 
 
893-862-B
5
 
Table 2 lists the most common cable and connector combinations 
for the 10BASE-FL media adapter, assuming the maximum 
permitted attenuation with ST connectors. The table lists the 
maximum (total) distance allowed in the fiber connection. 
However, your fiber connection may have to be shorter to meet 
the optical power budget and Ethernet repeater rules.
 
Table 2. 10BASE-FL cable and connector combinations
Number of in-line 
fiber-to-fiber 
connections
62.5/125-
 
µ
 
m
cable
50/125-
 
µ
 
m
cable
 
0
2000 m (6560 ft)
2000 m (6560 ft)
1
2000 m (6560 ft)
2000 m (6560 ft)
2
2000 m (6560 ft)
2000 m (6560 ft)
3
2000 m (6560 ft)
1710 m (5620 ft)
4
2000 m (6560 ft)
1430 m (4690 ft)
5
2000 m (6560 ft)
1140 m (3750 ft)
6
1750 m (5740 ft)
860 m (2810 ft)
7
1500 m (4920 ft)
570 m (1870 ft)
8
1250 m (4100 ft)
290 m (940 ft)
9
1000 m (3280 ft)
0
10
750 m (2460 ft)
11
500 m (1640 ft)
12
250 m (820 ft)
13
0
 
893-862-B SMF MDA  Page 5  Monday, September 30, 1996  1:32 PM