Nortel Networks Option 11C Manual Do Utilizador

Página de 546
M2317 Telephone
Page 279 of 544
Figure 29
Block diagram of M2317
Data communication
The M2317 can be equipped with an Asynchronous Data Option which will 
permit the use of either the telephone's dial pad or the feature keys to place 
and terminate data calls in the asynchronous mode. The Data Option also 
supports keyboard dialing from the data terminal when that terminal operates 
in the asynchronous mode.
553-1291
(W-BL)
(BL-W)
(W-G)
(G-W)
(BK-G)
(G-BK)
(BK-S)
(S-BK)
Line Cord
to Telephone
Tip
Ring
G
R
T0
R0
T1
R1
T6
R6
T7
R7
To Telephone
To Telephone
To Telephone
Cross-connect Block
Part of multi-pair Cable
Part of Shelf
Wiring Harness
Shelf Connector
16
40
13
38
 3
28
26
1
PE Shelf
Line Pack
Pack Connector
T0
R0
T1
R1
T6
R6
T7
R7
Unit 0
Unit 1
Unit 6
Unit 7
TELADAPT
Connecting Block