 Chapter 3 — System and site requirements
Page 47 of 332
Option 11C Mini
Planning and Installation Guide
Fasten the mounting bracket for each chassis to the piece of plywood with the 
five, 1 in. #14 screws supplied with the bracket. 
“Chapter 8 — Bracing the Option 11C Mini against earthquakes” on 
page 105
 of this guide contains a detailed procedure for earthquake bracing.
Grounding requirements
Before you install an Option 11C Mini and before you apply AC power, 
measure the impedance of the building ground reference. An ECOS 1023 
POW-R-MATE, or another meter like the POW-R-MATE, is acceptable for 
this purpose. If the ground path connected to the Option 11C Mini has an 
impedance of 5 Ohms or more, make better grounding arrangements. Make 
any improvements to the grounding system before you install the Option 11C 
Mini.
Table 9
Minimum fastener requirements
Type of wall
Fasteners
Wooden studs
#10 wood screws
Embedded a minimum of 1 
in. in wood studs
Metal studs
# 14 sheet metal 
screws
Embedded a minimum of 1 
in. in metal studs
Concrete
(2000 PSI)
1/4 in. HILTI KB-II
Embedded a minimum of 
1 1/8 in.
Masonry
1/4 in. Ramset 
Redhead Dynabolt 
sleeve anchor
WARNING
Failure to follow grounding recommendations can result in a system 
installation that is:
• unsafe for personnel working on, or using the equipment
• not protected correctly from lightning or power transients
• subject to service interruptions