Farallon Communications 412 Manual Do Utilizador

Página de 162
C-1
Appendix C
Technical Specifications
Physical dimensions
Dimensions:
8.66" (w) x 5.44" (d) x 1.56" (h) 
(22cm x 13.8cm x 4cm)
Specifications for Connectors
Computer por t:
RS-232-D with DB-25 connector
Analog device por ts:
Two RJ-11 modular jacks, suppor t 
three analog devices (including 
phone, fax, modem, and answering 
machine) per por t within 200' (61m)
ISDN por t:
ISDN BRI (2B+D) with integrated NT1 
“U” inter face
Power requirements
Power input: 
9V DC (external power adapter)
Power brick output:
9V DC @ 600mA
Environmental operating range
Operating temperature:
50
°
 to 122
°
 F (10
°
 to 50
°
 C)
Storage temperature:
-40
°
 to 149
°
 F (-40
°
 to 65
°
 C)
Relative storage humidity:
Up to 90% non-condensing