Telenetics 9.6 Manual Do Utilizador

Página de 31
 
MIU Installation, Operation & Diagnostics     Edition:  January 25, 1999              Page 5
 
 
3.    GENERAL PRODUCT SPECIFICATIONS 
 
Dimensions:  
 
 
 
5.3 x 4.0 x 1.375 inches 
Weight: 
    1 
lb 
 
Voltage Supply: 
 
 
8 to 24 VDC 
 
     7 
to 
16 
VAC, 
50/60 
Hz 
 Optional Wall Transformer 
115 VAC, 50/60 Hz 
 
Current Requirements:  (See Section 4 for Power Down Modes) 
 
MIU PowerPort 2.4: 
12VDC 
24VDC      125VDC 
120VAC        220VAC 
65mA 
27mA      7.5mA 
6.5mA          5.5mA 
 
MIU PowerPort 9.6:  
12VDC 
24VDC       125VDC 
120VAC        220VAC 
115mA 
57mA       11mA 
10mA          9mA 
 
MIU1 PowerPort 4.4: 
12VDC 
24VDC       125VDC 
120VAC        220VAC 
160mA 
69mA       14mA 
12mA          9mA 
 
MIU PowerPort 28.8: 
12VDC 
24VDC       125VDC 
120VAC        220VAC 
205mA 
125mA       16mA 
15mA          11mA 
 
 
Surge Protection: 
Power Supply:  8kVrms 
 
 
 
Analog Line: 
5kVac (MIU2.4 & 9.6) 
     3.75kVac 
(MIU14.4 
28.8) 
   Digital 
Line: 
ESD 
± 
10kV 
 
Operating Temperature: 
 
-40 to +85 deg C 
Operating Humidity:   
 
0 to 90% (non-condensing.) 
Storage Temperature:  
 
-55 to 100 deg C 
* Note: At temperatures below 0
° F, an additional current drain of up to 350   ma 