Delta Electronics VFD-XXXM Manual Do Utilizador

Página de 22
English-3 
 
Voltage Class 
575V Class 
Model 
Number 
VFD-XXXM 
007 015 022 037 055 075 
Max. Applicable Motor Output (kW)
0.75 
1.5 
2.2 
3.7 
5.5 
7.5 
Max. 
Applicable 
Motor 
Output 
(hp) 
1.0 2.0 3.0 5.0 7.5  10 
Rated 
Output 
Capacity 
(kVA) 
1.7 3.0 4.2 6.6 9.9 12.2 
Rated 
Output 
Current 
(A) 1.7 3.0 4.2 6.6 9.9 12.2 
Maximum Output Voltage (V)
3-phase Proportional to Input Voltage 
Output Frequency (Hz) 
0.1~400 Hz 
Outp
ut Rati
ng 
Carrier Frequency (kHz) 
1-10 
3-phase 
Rated Input Current (A) 
2.4 4.2 5.9 7.0 10.5 12.9 
Rated Voltage, Frequency 
3-phase 500~600 VAC, 50/60Hz 
Voltage Tolerance 
-15%~+10% (425~660 VAC) 
Inpu
t Ratin
g
 
Frequency Tolerance 
±
5% (47~63 Hz) 
Cooling Method 
Fan Cooled 
Weight 
(kg) 
1.5 1.5 2.0 3.2 3.2 3.3 
 
General Specifications 
Control System 
SPWM (Sinusoidal Pulse Width Modulation) control (V/F or sensorless vector 
control) 
Freq. Setting Resolution 
0.1Hz 
Output Frequency 
Resolution 
0.1Hz 
Torque Characteristics 
Including the auto-torque, auto-slip compensation; starting torque can be 150% at 
5.0Hz 
Overload Endurance 
150% of rated current for 1 minute 
Skip Frequency 
Three zones, settings range 0.1-400Hz 
Accel/Decel Time 
0.1 to 600 seconds (4 Independent settings for Accel/Decel Time) 
Stall Prevention Level 
Frequency Setting 
20 to 200%, Setting of Rated Current 
DC Injection Braking 
Operation frequency 0-60Hz, output 0-100% rated current 
Start time 0-5 seconds, stop time 0-25 seconds 
Braking Torque 
Approx. 20% (up to 125% possible with option brake resistor or brake unit 
externally mounted, 1-15HP braking transistor built-in) 
C
ontr
o
l C
h
ar
acter
isti
cs
 
V/F Pattern 
Adjustable V/F pattern 
Keypad Setting 
by 
 
Frequency 
Setting 
External 
Signal 
Potentiometer-5K
Ω/0.5W, 0 to +10VDC, 4 to 20mA RS-485 interface; Multi-
Function Inputs 0 to 5 (7 steps, Jog, up/down) 
Keypad 
Set by RUN, STOP 
Operation 
Setting 
Signal 
External 
Signal 
M0 to M5 can be combined to offer various modes of operation, RS-485 serial 
interface (MODBUS). 
Multi-Function Input Signal 
Multi-step selection 0 to 7, Jog, accel/decel inhibit, first to forth accel/decel 
switches, counter, PLC operation, external Base Block (NC, NO), auxiliary motor 
control is invalid, selections, driver reset, UP/DOWN key settings, sink/source 
selection 
Multi-Function Output 
Indication 
AC drive operating, frequency attained, non-zero, base block, fault indication, 
local/remote indication, PLC operation indication, auxiliary motor output, driver is 
ready, overheat alarm, emergency stop 
Oper
ati
ng C
har
acter
ist
ics 
Analog Output Signal 
Analog frequency/current signal output. 
Alarm Output Contact 
1 Form C contact or open collector output 
Operation Functions 
AVR, S-Curve, over-voltage, over-current stall prevention, fault records, adjustable 
carrier frequency, DC braking, momentary power loss restart, auto tuning, 
frequency limits, parameter Lock/Reset, vector control, counter, PID Control, PLC, 
MODBUS communication, reverse Inhibition, abnormal reset, abnormal re-start, 
digital frequency output, sleep/revival function, 1st/2nd frequency source selections