•   BCnet sectional control panel with 
two integrated loop interfaces
•   Extends a BCnet sectional control 
panel BC216-2 or BC216-3 by two 
loops
•   Analogue ringbus technology with 
unshielded detector cabling
•   Easy installation, also possible later 
on
Fire is a permanent threat to life and property. There-
fore, immediate response to a fi re is imperative. The 
main objective of the fi re detection control panel Series 
BC216  is  to  alarm  and  to  react  in  time  and,  conse-
quently, save lives and protect property. For decades 
LST have focused their aims to undertaking unrivaled 
efforts in order to realize new innovations in the security 
area. Research, development and production are loca-
ted within LST premises, thus guaranteeing fl exible and 
reliable individual solutions.
Using a 32-bit multiprocessor system, the fi re detection 
control panel Series BC216 ensures topmost effi ciency 
and speed – prerequisites for saving lives and minimi-
zing damage to property.
Description
The BCnet Sectional Control Panel/Extension BCE216-
3LG allows for the extension of a fi re detection control 
panel BCnet216 by two ADM loops. The extension is in-
tegrated into the fi re detection control panel BCnet216 
by installing it in a BCnet sectional control panel BC216-
2 or BC216-3 and connecting it to the GSSnet cabling 
via the GSSnet interface on the extension.
The 24V supply of the BCnet Sectional Control Panel/Ex-
tension BCE216-3LG is powered from the BCnet sectio-
nal control panel in whose cabinet it has been installed; 
it does not have a power supply or battery charger of 
its own. The extension is designed as compact unit and 
mounted on a pivoting sheet steel carrier.
The loop processing functions of the BCE216-3LG fully 
correspond to the functions of a BCnet Sectional Con-
trol Panel BC216-2 equipped with two Loop Interfaces 
LIF64-1.
The ADM loop principle offers intelligent analogue ring-
bus  technology  with  bi-directional  data  transfer.  Each 
loop provides for the software-aided administration of 
up to 198 physical address points in a maximum of 128 
detector zones.
Easy  parameterisation  by  means  of  PC  software  en-
ables you to optimally adapt the control panel to your 
individual requirements.