Dialogic TX4000 PCI SS7 Manual Do Utilizador
TX 4000 PCI SS7 Network Interface Board Installation Manual
Establishing network connections
Connecting to the network
Before connecting a TX 4000 board to the network, ensure that you have properly
configured the trunks as either T1 or E1. For configuration information, refer to the
Dialogic® NaturalAccess™ Signaling Software Configuration Manual.
configured the trunks as either T1 or E1. For configuration information, refer to the
Dialogic® NaturalAccess™ Signaling Software Configuration Manual.
Caution: Dialogic obtains board-level approval certificates for supported countries. Some countries
require that you obtain system-level approvals for boards connected to the public network.
To learn what approvals you require, contact the appropriate regulatory authority in the
target country.
To learn what approvals you require, contact the appropriate regulatory authority in the
target country.
Use a shielded RJ-45 cable to connect a TX 4000 board to a T1 network or to an E1-
120 ohm network. Complete the following steps to connect a TX 4000 board to the
120 ohm network. Complete the following steps to connect a TX 4000 board to the
network:
Step
Action
1
If connecting Trunk 1 or Trunk 2, connect a shielded RJ-45 cable directly to the board.
If connecting Trunk 3 or Trunk 4, use dual T1/E1 120 ohm trunk adapter cables to connect to
the board. Each trunk adapter cable divides the 8-pin modular jack on the end bracket into two
RJ-48C connectors. If you are connecting both jacks, use two cables, otherwise, just use one.
the board. Each trunk adapter cable divides the 8-pin modular jack on the end bracket into two
RJ-48C connectors. If you are connecting both jacks, use two cables, otherwise, just use one.
Note: TX 4000 boards are configured as T1/E1 120 ohm boards. To connect a TX 4000 board as
an E1 75 ohm board, use a balun transformer to convert the impedance from 120 ohm to 75
ohm. No other configuration changes are required. For more information, contact a Dialogic
Services and Support representative.
an E1 75 ohm board, use a balun transformer to convert the impedance from 120 ohm to 75
ohm. No other configuration changes are required. For more information, contact a Dialogic
Services and Support representative.
2
Connect shielded RJ-45 cables directly to the trunk connector on the board or to the dual T1/E1
trunk adapter cable.
trunk adapter cable.
Caution:
Failure to use a shielded cable may negate your approval.
The following illustration shows the cabling required to connect all four trunks on the
TX 4000 board:
TX 4000 board:
T r u n k s 1 a n d 3
T r u n k s 2 a n d 4
E t h e r n e t 2
E t h e r n e t 1
TX 4000 board
D u a l T 1 / E 1 1 2 0 o h m
a d a p t e r c a b l e s
S h i e l d ed R J - 4 5 c a b l e s
For more information, refer to dual T1/E1 120 ohm adapter cable on page 30.
Dialogic Corporation
31