Xantech 590-00 Manual Do Utilizador

Página de 6
6
• By plugging the Model 781C-00 power supply into the switched AC outlet on the back of a stereo receiver,
a constant 12V DC is applied to the 599.  The 599 generates a short pulse (+12V, 100 mSec) at its 
ON
terminal when it first sees +5 to +30V DC at its IN+ and IN– terminals (the stereo receiver is turned on).
• Similarly, it will generate a short pulse at its 
OFF
 terminal (+12V, 100 mSec) when the +5 to +30 volts drops
to 0 volts (the stereo receiver is turned off).
 • This short pulse operation also permits momentary switches to be connected to other inputs on the 590
(such as inputs 1 and 2, as in 
Fig. 2
).  This allows additional system commands, other than those activated
by the 599, to be executed uninhibited.
Fig. 3
  shows another example of how a DC control voltage is converted to momentary ON and OFF pulses
by the 599 Pulsed Switching Module.
• For instance, a special SPST sensing switch, as shown, could be mounted in the springs of an over-stuffed
chair.
• When someone sits down in the chair, the SPST switch is closed causing the 599 to trigger a sequence
of IR commands stored in the 590.  The IR commands could cause the room lights to dim, the drapes to
close, and music to emanate from the speakers.
• When the chair is no longer occupied, the SPST switch opens, triggering another set of sequenced
commands.  These, in turn, could cause the lights to brighten, the drapes to open & the music to turn off.
• Many other applications are possible, limited only by the imagination and needs of the installer and user.
--- IMPORTANT ---
• The 590 inputs that are to be activated by the 599 Pulsed Switching Module 
must first
 be programmed
with the necessary commands 
before
 connecting the 599.
• Do this by using the connections and procedures as previously mentioned.
• The 590 
cannot
 be programmed through the 599!
590-00 SPECIFICATIONS
• INPUTS:
16 Opto-Isolators connected via 16 screw terminal pairs, each in series with a 1k Ohm
resistor.  Input voltage range, 5 to 30 Volts DC.  All isolated - no common ground connec-
tions.
Drive current for each input is 11 mA at 12V DC.
12V DC is available on the 
12VDC
 "
+
" and "
" screw terminals for driving inputs through
external switch closures.
• BANKS:
Four.  16 commands per bank.
• IR OUT:
2  screw terminals marked "
O
" (output) and "
G
" (Gnd.). Same electrical
characteristics as Xantech IR Receivers and key pads.
• POWER IN: 12VDC, 300 mA.  2.1 mm coaxial jack, center positive.  Uses Model 786-00 Power Supply
(included).
• MEMORY:
64k RAM.  Lithium battery backup.
• IR CARRIER FREQUENCY:  21.74 kHz to 62.50 kHz learning bandwidth.
• Dimensions:  6 1/4" W x 2" H x 4" D
590-00