Yamaha AW4416 Manual Do Utilizador

Página de 507
EQ/ATT/GRP screen
56
        
— Reference Guide
Library page
Store or recall EQ settings
[Function]
Store EQ settings in the EQ library, or 
recall a stored EQ program.
[Key operation]
• [EQ] key → [F2] (Library) key
• Repeatedly press the [EQ] key until the 
screen shown at the right appears.
[Mouse operation]
M button → EQ button → Library tab
[Screen functions]
A
SEL CH
This indicates the currently selected channel.
B
EQ graph
This graphically displays the EQ settings.
C
Output meter
This meter shows the post-EQ output level.
D
TITLE EDIT button
Use this to edit the name (library title) of the EQ 
program stored in the EQ library. A library name 
of up to 16 characters can be input. Move the 
cursor to the TITLE EDIT button and press the 
[ENTER] key to access the TITLE EDIT popup 
window where you can input a name. For 
details on inputting characters, refer to Opera-
tion Guide P.60.
Library numbers 1–40 are recall-only preset 
memories, and their names cannot be 
changed. Numbers in which no EQ program 
has been stored are displayed as “No Data!,” 
and their title cannot be changed.
E
RECALL button
Recall the currently selected EQ program from 
the list.
If you attempt to recall a number in which no 
data has been stored, a message of “ERROR 
NO DATA TO RECALL” will appear, and the 
recall will not occur.
F
STORE button
Store the current EQ settings.
• Library numbers 1–40 are recall-only preset 
memories, and cannot be stored. You can 
store only in library numbers 41–128.
• When you store, the EQ program that was 
previously stored in that number will be 
erased.
Tip!
G
LIBRARY No. (library number)
This shows the library number 1–128.
H
LIBRARY TITLE
This shows the names assigned to each library 
number.
I
ROM
A write-protect symbol is displayed for recall-
only programs (library numbers 1–40).
1
4
5
6
J
K
7
8
9
3
2