System Troubleshooting
350-7951
Quadra User’s Guide
112
. .
 . 
.
Images have the wrong 
aspect ratio (e.g., are 
stretched) or are not 
positioned correctly
• 
Try selecting a different output from the “
” to better match your display.  
• 
Determine that there is not a mismatch between your 
output and the selected monitor display (e.g., 4:3 output 
and 16:9 display monitor).
• 
Use the “
” (WSR) and 
” (WDR) functions to 
check or modify the image’s aspect ratio.
Blank image (the output is 
black)
• 
Ensure that the source is properly connected to the system, 
powered on and generating a signal. 
• 
Ensure that the correct input type is selected using the 
” command. 
Frozen image
If an image is frozen after system start-up, turn freeze off using the 
” command. 
Missing imagery
• 
Check the “
” (WSR) value 
to ensure the entire image is being processed. 
• 
Check WSR and “
” 
(WDR) to ensure that the source and destination 
rectangles are delivering the entire video image.
Poor quality video
• 
Check the video source for proper operation. 
• 
Check that cables are in good condition and connected 
correctly.
• 
Ensure that video sources are not double terminated.  
Double termination can occur when one video source is 
split into two using a “T” connector instead of a 
distribution amplifier. 
• 
If you are using a VCR, check the quality of the tape.  
• 
Adjust the brightness using the “
” command.
• 
Adjust contrast using the “
” command. 
• 
Adjust saturation as required using the “
” 
command.
• 
Adjust the hue as required using the “
” command.
No color on the S-Video 
input
• 
Check that the “
 setting is set to normal.  
Adjust as necessary.
• 
Check that the S-video cable is connected correctly.
• 
Check that S-Video has been selected as the source using 
the “
” command.  If you select 
Composite2 when you have an S-Video signal connected 
to this port, the input will be displayed as a black and 
white (luminance only) signal.
Aspect Ratio on a video 
input is incorrect.
Check the status of the “
” command.  For a 4:3 
aspect ratio signal, this should be set to normal.
Table D-1. 
Troubleshooting Guide(Continued)
Symptom