6. 
Place a new chip. It must be the same chip as the master chip. 
7. 
The buffer still holds your master data and the memory portion. 
8. 
Click on Option again and set all the fuses that you wrote. 
9. 
(To change the option, use the arrow button in the selection box.) 
10. 
In the same Option menu, Click on the program configuration fuses
read and compare the fuses with your original device. 
CAUTION: The PIC16C711, will be used as an OTP (one time programmable) 
chip when you erase the secured device. You cannot reuse the chip after erasing 
it, even though the PIC16C711 is an  erasable device. 
ƒ 
MOTOROLA MC68HC908 devices
 
This device will require a security code in certain memory location when you 
program a new device along with data and users must remember the security 
data once read (copy)or verify  the master device for duplication. 
ƒ 
Serial EEPROMs 
These devices are electrically erasable, but they operate serially rather than 
parallel. 
ƒ 
Atmel or Xilinx 17xxx 
You need to set the POLARITY FUSE with this family via the Option menu. 
After programming the main MEMORY, go to the OPTION menu and make 
the appropriate change. On OTP (One Time Programmable) devices, the 
POLARITY FUSE status cannot be reversed once it has been changed.  Even 
on some of the windowed 7xxx family devices (excluding Xilinx 17xxD/L & 
17128), the POLARITY FUSE cannot be toggled. Consult the device 
manufacturer for further instructions on how to handle the Polarity FUSE. 
CAUTION: Do not touch or remove a device during an operation when the 
BUSY green led is on.