ZyXEL Communications 2 Plus Manual Do Utilizador

Página de 686
 Chapter 29 WAN and Dial Backup Setup
ZyWALL 2 Plus User’s Guide
489
after you enter the password, then you should create a third set to match the final “PPP...” 
but without a “Send” string. Otherwise, the ZyWALL will start PPP prematurely right after 
sending your password to the server.
If there are errors in the script and it gets stuck at a set for longer than the “Dial Timeout” in 
menu 2 (default 60 seconds), the ZyWALL will timeout and drop the line. To debug a script, 
go to Menu 24.4 to initiate a manual call and watch the trace display to see if the sequence of 
messages and prompts from the server differs from what you expect.
Figure 313   Menu 11.2.3: Remote Node Script
The following table describes the fields in this menu.
29.9  Remote Node Filter
Move the cursor to the field Edit Filter Sets in menu 11.2, and then press [SPACE BAR] to 
set the value to Yes. Press [ENTER] to open Menu 11.2.4 - Remote Node Filter
Use menu 11.2.4 to specify the filter set(s) to apply to the incoming and outgoing traffic 
between this remote node and the ZyWALL to prevent certain packets from triggering calls. 
You can specify up to four filter sets separated by commas, for example, 1, 5, 9, 12, in each 
filter field. Note that spaces are accepted in this field. Please refer to 
 
for more information on defining the filters. 
      Menu 11.2.3 - Remote Node Script
     Active= No
     Set 1:                               Set 5:
       Expect=                              Expect=
       Send=                                Send=
     Set 2:                               Set 6:
       Expect=                              Expect=
       Send=                                Send=
     Set 3:
       Expect=
       Send=
     Set 4:
       Expect=
       Send=
Enter here to CONFIRM or ESC to CANCEL:
Table 183   Menu 11.2.3: Remote Node Script
FIELD
DESCRIPTION
Active 
Press [SPACE BAR] and then [ENTER] to select either Yes to enable the AT strings or 
No to disable them.
Set 1-6: 
Expect 
Enter an Expect string to match. After matching the Expect string, the ZyWALL returns 
the string in the Send field.
Set 1-6: 
Send 
Enter a string to send out after the Expect string is matched.