Adtran MX2800 M13 Manual Do Utilizador

Página de 200
3-40    
61200290L1-1G
Section 3, Configuration
MX2800 M13 Multiplexer User Manual
Load All Default Settings
This option defaults all settings for the unit. Once the settings have been successfully retrieved, Command 
Accepted will appear at the bottom of the screen
CAUTION
The User Account Management table is also reset to default.
Updating Software
Select 
Update Flash Software
 from the Utilities menu to update software, using either XModem protocol 
or TFTP.
NOTE
Before beginning update of Flash software, disable the Auto Save feature
of the MX2800. From the 
Configuration
 menu, choose 
System
Management
, then select 
Auto Save
 and toggle until it is set to 
Disable
.
Update Via XModem
Updating the Flash Software via XModem requires that a VT100 terminal menu session be active through 
the units craft port. To update the software via XModem, follow these steps:
1. From the MX2800 Main Menu, select 
Configuration
, then 
Utilities
, then 
Update Flash Software
, and 
then 
Update via XModem
2. Once it has been determined where the new binary file is located, select 
Start 
to begin the transfer.
3. Once 
Start
 has been selected, start the XModem transfer from the terminal menu program that is being 
used by selecting or typing the file path for the location of the new binary file. Refer to the appropriate 
documentation for the terminal emulator to begin XModem transfer.
4. After the binary file has been selected, the XModem transfer will begin. To cancel a transfer in 
progress, press 
C
TRL
+X
 three times. The 
ACT 
LED on the active card is solid amber for the duration of 
XModem transfer. The 
ACT
 LED on the standby card is flashing green.
5. If updating a unit with redundant controller cards, the active controller will begin uploading the new 
code to the standby controller after the XModem transfer has completed and the unit has successfully 
loaded and programmed the new software into its Flash memory. If the unit does not have redundant 
controller cards, go to 
6. While the standby card is having code uploaded, the 
ACT 
LED on the standby card will be solid 
amber. After the code has finished uploading to the standby card, the card will reset itself and begin 
running the new code.