ADC H2TU-C-388 Manual Do Utilizador

Página de 66
152-388-100-02, Issue 2
 
Testing
H2TU-C-388 List 1
June 6, 2000
 47
A3LB and A4LB Test Procedures
The H2TU-C-388 can be looped back by sending the Addressable Office Repeater (AOR) LPBK activation code 
1111-1111-0001-1110 (FF1E) for at least 5 seconds. This causes the H2TU-C-388 to enter the NLOC state. The 
Loopback Time-out setting (see 
) determines the duration of 
this loopback unless it is overridden by the reception of a second identical 16-bit loopup command before the timer 
expires. When this time-out override state exists, the only way to loop the H2TU-C-388 down is to issue one of 
the three loopdown commands listed in 
. The automatic time-out mode is restored during subsequent 
loopback sessions.
 summarizes the codes required to execute Addressable 3 (A3LB) and Addressable 4 (A4LB) repeater 
loopback commands. All code sequences must be present for at least 5 seconds.
Table 17.
Addressable Repeater Loopback Commands (A3LB and A4LB)
Name
Description
Binary Code
 (a)
 (Hexadecimal Equivalent)
(a) The leftmost bit arrives first in all sequences. The detection algorithm functions reliably with a random 10
-3
 BER on the facility. 
The entire arming and loopback sequence can also be initiated at the remote H2TU-R location.
NLOC
H2TU-C-388 loopup from NI
1111-1111-0001-1110 (FF1E)
CREM
H2TU-C-388 loopup from CI 
0011-1111-0001-1110 (3F1E)
NREM
H2TU-R loopup from NI
1111-1111-0000-0010 (FF02)
CLOC
H2TU-R loopup from CI
0011-1111-0000-0010 (3F02)
SMJK
H2TU-R loopup from NI
11000-11000-11000 ...
SMJK
H2TU-R loopup from NI
 (b)
(b) Not supported by A4LB.
100000 100000 100000 ...
SMJK
H2TU-R loopup from NI (ESF-DL)
1111-1111-0100-1000 (FF48)
Loopdown
H2TU-C and H2TU-R loopdown from NI OR CI
11100-11100-11100 ...
Loopdown
H2TU-C and H2TU-R loopdown from NI OR CI
100-100-100 ...
Loopdown
H2TU-C and H2TU-R loopdown from NI OR CI (ESF-DL)
1111-1111-0010-0100 (FF24)