ADC H2TU-C-388 Manual Do Utilizador

Página de 66
Appendix A - Specifications
 
 152-388-100-02, Issue 2
50
June 6, 2000
 H2TU-C-388 List 1
L
OOP
 A
TTENUATION
Each loop has no more than 35 dB of loss at 196 kHz, with driving and terminating impedances of 135
Ω
 (see 
 below). 
H
I
G
AIN
 L
INE
 U
NIT
 C
ARD
-E
DGE
 C
ONNECTOR
 shows the card-edge connectors on the HiGain Line Unit. Active pins are highlighted in black.
Figure 28.
HiGain Line Unit Card-Edge Connector
Network Management Control Bus
The H2TU-C-388 provides a Network Management Control Bus on pin 104 of the card-edge connector. This 
allows the various ADC Management System protocols to manage the H2TU-C through the HMU-319 HiGain 
Management Unit. Whenever the H2TU-C-388 is under management, the 
MNGD
 message displays periodically on 
the front-panel display.
Table 19.
HDSL2 Cable Attenuation Chart
Cable Gauge
Loss at 196 kHz (dB/kft)
Ω
 
per kft
26/0.4 mm
3.88
83
24/0.51 mm
2.84
52
22/0.61 mm
2.18
32
19/0.91 mm
1.54
16
Some HiGain Line Unit features are affected when it is under management. Consult the 
management unit practice for further information.
106
105
104
103
102
101
100
DSX-1 OUT
DSX-1 IN
HDSL2 Span
205
204
203
202
201
200
119
118
117
116
115
114
113
112
111
110
Ground
Ground
Frame ground
Fuse alarm*
Ring 1
Tip 1
Management bus
Ring
Ring 1
Tip
Tip 1
Factory burn-in
-48Vdc
219
218
217
216
215
214
213
212
211
210
209
208
207
206
109
108
107
* Fuse alarm is normally floating (0 to 80 Vdc max.) and
at -48 Vdc (10 mA max.) when activated.