Running Diagnostics from the Display Panel
To run the internal diagnostic programs from the T1 Modem Bank’s front panel, turn the T1 Modem Bank on and
wait for the POST (Power On Self Test) to complete. While 
P1 
is displayed on the front panel, press either button
on the display panel.
The first thing you should  see is the T1 Modem Bank’s node number. This will be displayed in the form 
xn
, where
is the node number (
1n
, 
2n
, and so forth). If you wish to change the node number, press the left push-button
repeatedly until the desired node number appears on the display, then press the right push-button to save it in
EEPROM. If the new node number is successfully written to EEPROM, 
Pn
 will be displayed to indicate a pass
condition. If the write operation failed, 
Fn
 will be displayed. See “Setting the Node Number” on page 27 for more
information about node numbers.
If you do not wish to change the node number at this time, press the right push-button again to proceed to the Line
Card test without rewriting the node number.
If you do not wish to change the line card configuration at this time, press the right push-button again to proceed to
diagnostic Test 1 without changing the line card configuration.
Pressing the right push-button repeatedly will cycle through all of the test numbers without executing the tests. To
execute a test, press the left push-button while the desired test number is displayed. The left decimal point of the 7-
segment display will be turned on to indicate that a test is in progress. Table 4 on page 30 shows the possible codes
that could appear in the display panel window when a diagnostic test is performed. Note that codes E0 and E2
through E6 indicate a hard failure. This is a system failure;  the test will not continue.
Errors are counted on the ten LED indicators. The error count is a binary number, with the LSB (Least Significant
Bit) on the left  and the MSB (Most Significant Bit) on the right. Note that in tests 2, 4, 5, 6 and 7, when the test is
stopped (by pressing the left push-button), the error count is replaced by diagnostic information. Write down the
status of the LED indicators so the information is available in case you need to contact Digi  Technical Support.
To stop running a test in progress, push the left push-button again. The test will terminate, and the 7-segment display
will show the test number preceded by P (pass) or F (fail).
To exit diagnostic test mode and return to the initialized state, cycle the T1 Modem Bank’s power off, then on again.