Adtran DSU 56 Manual Do Utilizador

Página de 44
Chapter 3.  Test Modes
3-8
DSU 56/64 User Manual
61200062L1-1
Test Pattern (PTRN)
When the 
PTRN
 test is initiated, the local DSU 56/64 uses the 
integral test pattern generator to transmit a standard 2047 test 
pattern to the DSU on the far end of the circuit. The local DSU 56/
64 then examines the received data for the standard 2047 pattern. 
Once this pattern is detected and synchronization is achieved, the 
E
RROR
 indicator is turned off. The 
E
RROR
 
indicator turns on when 
errors in the receive data pattern are detected. While this test is 
active, errors can be injected into the transmit data stream by 
pressing the 
S
ELECT
 push-button. The 
PTRN LED
 flashes during 
initialization of the test and turns on solid once the test is in 
progress. 
To initiate the 
PTRN
 test, perform the following steps:
1. Press
 S
ELECT
 
seven times to turn on the 
PTRN
 test indicator.
2. Press 
the 
T
EST
 
switch while this test indicator is on. 
3.  To terminate this test, press 
T
EST
.