Adtran Express XL Manual Do Utilizador

Página de 187
Chapter 3: Terminal Menu Operation and Structure
61200070L1-1
Express XL/XLT User Manual
79
Samples/Time Between Changes
Write security: 3; Read security: 5
This value is the minimum time between bandwidth changes for this Connec-
tion List profile.  The range is 0 to 255 seconds.  The default is 60 seconds.
Connection List/Filters
The Express XL/XLT can block packets in and out of a WAN port by use of the 
filters.  These filters are set up on a per-Connection List profile basis.  They are 
set up in two steps: 1) define the types of packets that would be of interest in 
the Configuration/Security/Filter Defines menu, and 2) set up the filter type 
and combination of defines that will cause a packet block.
Typical example of a filter setup:
Filters/WAN-to-LAN (In)
Write security: 2; Read security: 5
The packets which come into the Express XL/XLT can be filtered in three 
ways:
Disabled
 (def) - Turns off packet input filtering. No incoming
packets are blocked.
Block All
 - All incoming packets from the WAN are blocked
except as defined in the Filters/In Exceptions list.
Forward All
 - All incoming packets from the WAN are not
blocked except as defined in the Filters/In Exceptions list.