Lucent Technologies 6000 Manual Do Utilizador
4-114
MAX 6000/3000 Network Configuration Guide
Configuring Individual WAN Connections
Configuring POTS capability on the MAX 6000 and MAX 3000
Configuring POTS capability on the MAX 6000 and MAX 3000
Example of a Numbering Plan profile
With the following configuration, the MAX expects eleven digits for all phone numbers
beginning with a 1, and seven digits otherwise. Callers do not need to press the # key after
entering the phone number.
beginning with a 1, and seven digits otherwise. Callers do not need to press the # key after
entering the phone number.
System
Numbering Plan
NPprofile1
Name=NPprofile1
Active=Yes
Dial Prefix=N/A
Number Digits=7
System
Numbering Plan
NPprofile2
Name=NPprofile2
Active=Yes
Dial Prefix=1
Number Digits=11
MAXDAX
MAXDAX routing provides increased flexibility in routing network-to-network calls. This
release extends this flexibility to calls originated from POTS ports.
release extends this flexibility to calls originated from POTS ports.
To use the MAXDAX functionality for POTS calls, proceed as follows:
1
Assign channel group numbers to each channel that can be used for an outgoing call. For
example:
example:
Net/T1
Line Config
Line Config profile
Line 1
Net2Net ChanGroup ID
Ch 1=Switched
Ch 1 ChanGroup=2
Ch 2=Switched
Ch 2 ChanGroup=4
2
Create a Call Routes profile that will match all calls to which you want to apply the
MAXDAX functionality. Within this profile, define the appropriate destination channel
group. For example:
MAXDAX functionality. Within this profile, define the appropriate destination channel
group. For example:
System
Call Routes
CRprofile1
Name=CRprofile1
Active=Yes
Dst Chan Grp=2
System
Call Routes
CRprofile 2
Name=CRprofile 2