Testing Your Location Configuration
8-14
PortMaster Configuration Guide
Testing Your Location Configuration
When you are configuring a location, you can set a manual connection for the location 
so that you can test the configuration before resetting the connection to on-demand or 
continuous. To test the configuration, you must initiate a connection with the remote 
location by using the dial command from the command line. 
To display the chat script (if you are using one) during dialing, use the optional -x 
keyword. You can watch the connection process to ensure that location-specific settings 
are configured correctly. This keyword also resets some debugging values previously set 
with set debug.
When your location is configured correctly, change the connection type from manual to 
continuous or on-demand.
To test your configuration, use the following command:
Command> dial Locname [-x]