Frame Relay Subinterfaces
13-14
PortMaster Configuration Guide
Troubleshooting Subinterfaces
Packets received on a subinterface can be identified as belonging to that subinterface 
only if the DLCI is properly entered in the DLCI table for that location. If you are having 
problems, do the following:
Wait a few moments. Subinterfaces come up after the primary interface. This 
process can take a few moments.
Check the list of DLCIs tied to each location using the show location Locname 
command.
Verify the DLCI list on a location using the show arp Interface command, replacing 
Interface with the name of the interface. A list of interfaces can be shown with the 
ifconfig command.
Always reset the port after changing the DLCI list.
Verify that all DLCIs are accounted for by checking the DLCI list for your primary 
interface. If you enter the wrong DLCI for the subinterface, the DLCI for the 
subinterface is applied to the primary interface if LMI or Annex-D is in use. 
Enter the following two commands to view the LMI or Annex-D keepalives:
Command> set console s1
Command> set debug 0x51
After you verify that the proper keepalives are being received, enter the following 
commands to turn off the debug utility:
Command> set debug off
Command> reset console
If you have a Cisco router on the other end of your connection, verify that it is set 
for encapsulation
 
frame-relay ietf for the serial interface; otherwise, the Cisco 
frame-relay map command for your DLCI must have the ietf keyword appended.