Using Synchronous V.25bis Connections
14-7
Configuration Steps for a Synchronous V.25bis Connection
Note – Configuring the maximum ports setting to a value higher than 0 causes the 
PortMaster to dial out to a continuous location, or become available for dial-out to an 
on-demand location. By configuring the maximum ports setting last, you ensure that 
the PortMaster will not attempt to make a connection with a location until you have 
configured all the settings for that location. 
After you configure location table settings as shown in Table 14-5, enter the following 
command to save the configuration:
Command> save all
For more information about configuring location table settings, refer to Chapter 8, 
“Configuring Dial-Out Connections.”
Configuring the PortMaster in Miami
The PortMaster in Miami is being configured for a V.25bis dial-up synchronous 
connection to the PortMaster in Boston.
Idle timer
set location miami idle 5
Dial group
set location miami group 1
Username
set location miami username miami
Telephone number
set location miami telephone 5551212
Password
set location miami password anypasswd
High-water mark
set location miami high_water 0
Maximum ports
set location miami maxports 1
Table 14-5
Location Table Values (Continued)
Setting
Command