Lantronix 900-422 Manual Do Utilizador

Página de 87
6: Configuration Using Telnet or Serial Port (Setup Mode) 
 XPress DR+ User Guide 
45 
Windows: telnet x.x.x.x 9999 
UNIX: telnet x.x.x.x:9999 
 
2. Click 
OK. The following information displays. 
Figure 6-1. MAC Address  
 
 
3.  To enter Setup Mode, press Enter within 5 seconds. The current configuration 
settings display, followed by the Change Setup menu. 
Figure 6-2. Setup Menu Options 
 
4.  Select an option on the menu by entering the number of the option in the Your 
choice ? field and pressing Enter.  
5.  To enter a value for a parameter, type the value and press Enter, or to confirm a 
current value, just press Enter.  
6.  When you are finished, save the new configuration (option 9). The unit reboots.  
Serial Port Connection 
To configure the unit through a serial connection:  
1.  Connect a console terminal (VT100) or PC running a terminal emulation program 
from port 1 with the Lantronix supplied P/N: 500-103 RJ45-to-DB9F serial cable. 
 
2.   The default serial port settings are 9600 baud, 8 bits, no parity, 1-stop bit, no-flow 
control
3.  Reset the XPress DR+ unit by cycling the unit's power (turning the power off and 
back on). Immediately upon resetting the device, enter three lowercase x characters 
(xxx). 
Note:
 The easiest way to enter Setup Mode is to hold down the key at the 
terminal (or emulation) while resetting the unit. You must do this within 
three seconds of resetting the XPress DR+
At this point, the screen display is the same as when you use a Telnet connection. To 
continue, go to
 