103
M
ODULES
> T
YPE
Write security: 3; Read security: 5
Displays the type of module actually installed in the slot or the type of module you plan to install in the
slot. The ATLAS 550 controller automatically detects the type of module installed in each slot, and the
slot. The ATLAS 550 controller automatically detects the type of module installed in each slot, and the
T
YPE
field automatically defaults to the installed module type. You can also use this field to preconfigure a
unit before actually installing modules by specifying the module that you want to install in each slot.
To use this option, navigate to the field you want to edit and press <Enter>. For empty slots, a list of all the
available module types displays. Select the one you want and it displays in the
available module types displays. Select the one you want and it displays in the
T
YPE
field. If this field is
already configured with a module, you can only set this field to
E
MPTY
. To change from one module type to
another, you must first set the field to
E
MPTY
.
M
ODULES
> M
ENU
Read security: 5
Displays additional status and configuration menus for the ATLAS 550 controller or selected module. To
access the submenus for this item, use the arrow keys to scroll to the
access the submenus for this item, use the arrow keys to scroll to the
M
ENU
column for the module you
want to edit, and press <Enter>. For detailed information on each submenu item for a particular module,
refer to the modules menus discussion for the appropriate option or resource module.
refer to the modules menus discussion for the appropriate option or resource module.
M
ODULES
> A
LARM
Read security: 5
Displays whether there is an alarm condition on the ATLAS 550 controller or selected module. Press
<Enter> to access the
<Enter> to access the
A
LARM
menu. For detailed information on each submenu item for a particular
module, refer to the following sections for the appropriate option or resource module alarm menu
discussions.
discussions.
M
ODULES
> T
EST
Read security: 5
Displays whether the ATLAS 550 controller or selected module is executing a test. Press <Enter> to access
the
the
T
EST
menu. This option will allow you to set up and initiate tests. You may also access this menu
through the
M
ENU
submenu on this screen. For detailed information on each submenu item for a particular
module, refer to the
T
EST
sections for the appropriate option or resource module test menu discussions.
M
ODULES
> S
TATE
Read security: 5
Displays whether the ATLAS 550 controller or selected module is online or offline. Even though a module
is physically installed, it must be marked
is physically installed, it must be marked
O
NLINE
for it to be considered an available resource. This
parameter allows an installed module to be marked
O
FFLINE
, which may be useful in system
troubleshooting. If you choose
O
FFLINE
, the module will not be in alarm condition, but will display
O
FFLINE
. While in
O
FFLINE
,
the
STATUS
LED will flash green. A module will automatically change to the
O
NLINE
state when installed.