Adtran 1200305L1 Manual Do Utilizador
ATLAS 550 System Manual
Section 4, User Interface Guide
61200305L1-1F
© 2002 ADTRAN, Inc.
129
M
ODULES
(T1/PRI-2/4) > T
EST
> R
EMOTE
LB
Write security: 4; Read security: 5
Sends loopback code to remote CSU. The following options are available:
M
ODULES
(T1/PRI-2/4) > T
EST
> P
ATTERN
Write security: 4; Read security: 5
Test pattern to be transmitted out the port. The following options are available:
M
ODULES
(T1/PRI-2/4) > T
EST
> QRSS/RLB R
ESULTS
Write security: 3; Read security: 5
Displays current status of T1 tests including information regarding loopbacks and test patterns. When
displaying test pattern status, the display string is composed of pattern sync status and errored seconds.
displaying test pattern status, the display string is composed of pattern sync status and errored seconds.
M
ODULES
(T1/PRI-2/4) > T
EST
> C
LR
Write security: 3; Read security: 3
Clears error counters on test pattern results menu.
M
ODULES
(T1/PRI-2/4) > T
EST
> I
NJ
Write security: 3; Read security: 3
Injects errors into transmitted test pattern.
Selection
Framing
Description
AT&T I
NBAND
LINE
ESF/D4
Full 1.544 Mbps loopback of the signal received from the network
(metallic loopback).
(metallic loopback).
ANSI FDL L
INE
ESF
Full 1.544 Mbps loopback of the signal received from the network.
Initiated through loopback activation transmission over the facility
data link (FDL).
Initiated through loopback activation transmission over the facility
data link (FDL).
ANSI FDL P
YLD
ESF
1.536 Mbps loopback of the payload data received from the network
maintaining bit-sequence integrity for the information bits by
synchronizing (regenerating) the timing. Initiated through loopback
activation transmission over the facility datalink (FDL).
maintaining bit-sequence integrity for the information bits by
synchronizing (regenerating) the timing. Initiated through loopback
activation transmission over the facility datalink (FDL).
I
NBAND
NIU
ESF/D4
Full 1.544 Mbps loopback of the signal received from the network
after passing through the T1 framer of the remote unit.
after passing through the T1 framer of the remote unit.
A
LL
ONES
Framed ones
A
LL
ZEROS
Framed zeros
QRSS
Pseudo-random pattern with suppression of excess zeros
N
ONE
No sync.
LOS
Sync has been lost.
S
YNC
Pattern is synchronized.
ES
Number of seconds with at least one bit error.