Adtran 1200305L1 Manual Do Utilizador

Página de 430
ATLAS 550 System Manual
Section 4, User Interface Guide
61200305L1-1F
© 2002 ADTRAN, Inc.
263
D
IAL
 P
LAN
 > G
LOBAL
 P
ARAM
 > E
ND
 
OF
 N
UMBER
 T
IMEOUT
Write security: 3; Read security:  5
Sets the length of time ATLAS 550 waits before assuming the outgoing dialed number is complete. The 
default value is six seconds. This timeout will only be invoked if the dialed number does not match one of 
the patterns set in the 
N
UMBER
 C
OMPLETE
 T
EMPLATE
 menu (see Nbr Complete Templates below).
D
IAL
 P
LAN
 > G
LOBAL
 P
ARAM
 > C
OUNTRY
 C
ODE
Write security: 3; Read security:  5
The country code. Enter your international country code using only digits. For the United States, enter 1.
D
IAL
 P
LAN
 > G
LOBAL
 P
ARAM
 > A
REA
 
OR
 C
ITY
 C
ODE
Write security: 3; Read security:  5
The local area code. Use for sending caller ID to the network. 
D
IAL
 P
LAN
 > G
LOBAL
 P
ARAM
 > N
BR
 C
OMPLETE
 T
EMPLATES
Write security: 3; Read security:  5
Sets completed number patterns for outgoing calls so that ATLAS 550 recognizes when the phone number 
is complete. Fields include the index number (#) and 
P
ATTERN
. For example, a local number will be 7 
digits long while a long distance (1+ area code + number) will be 11 digits long. The ATLAS 550 defaults 
cover almost any installation, and these templates should not require any additional user input – except for 
unusual circumstances. The template allows the use of the following wildcard inputs to define numbers:
D
IAL
 P
LAN
 > G
LOBAL
 P
ARAM
 > N
UMBER
 T
YPE
 T
EMPLATES
Write security: 3; Read security:  5
Sets call type patterns. ISDN interfaces require that a number type be sent over the D channel when a call 
is sent or received. A normal RBS trunk does not send a type designator, but uses prefixes instead. For 
example, “1 +” prefix is a national long distance call type while a “011 +” prefix is an international long 
distance call type. These templates form a table to permit ATLAS 550 to translate the RBS prefix into a 
call type for ISDN and vice-versa.
D
IAL
 P
LAN
 > G
LOBAL
 P
ARAM
 > N
UMBER
 T
YPE
 T
EMPLATES
 > #
Write security: 3; Read security:  5
Denotes an entry number. The maximum number of entries is 50. Press < I > to insert a new entry and
< D > to delete any entry.
X   
=   Any single digit 
= Any single digit 2 through 9
911
= This specific number
[1,2,3...] 
= A single digit in this group
The ATLAS 550 default templates should cover all applications and should not need to be 
added to by the user except for very rare circumstances.