McDATA UltraNet Edge 3000 User Guide
Delivering the Configured Network
Channel Switch application for each node. If you create a second 
data path for the Fibre Channel Switch interfaces, the previously 
configured data path will be deleted.
The options selectable from this dialog box are limited by the 
license key for the node. If the license key does not provide 
support for the Fail Over and Load Balancing network routing 
types, only the Dedicated Circuit network routing type is 
selectable, and all other options on this dialog are grayed out.
If you want to change the Network Routing Type after you have 
created the data paths, double-click the F/C interface on the 
Network Map. Click the Network button at the bottom of the F/C 
interface dialog box (FCSW10_2 - Node10) and select the 
Network Routing Type. You do not need to create the data paths 
again to change the Network Routing Type.
If you have not entered the licensing information for each node in 
the circuit using the License Wizard, only the Dedicated Circuit 
network routing type is selectable from this dialog box.
12. Proceed to the “Delivering the Configured Network” section in 
this chapter.
Delivering the Configured Network
Now that you have configured a sample network, or if you made 
changes to the configuration parameters, you must deliver the 
configuration information for each node defined on the active 
network map to the actual nodes.
The configuration information can be delivered in two different 
ways, File>Deliver Network or File>Delivery Wizard.
The configurations can be delivered via the Maintenance Port IP or 
the PPP Port IP. If you do not have direct IP connectivity, use the PPP 
option. See “Setting the Delivery Properties” below.
NOTE: 
procedure in Appendix H, complete the “Update UltraNet ConfigManager 
with the Manual Configurations” pr
ocedure before delivering the configured 
network.