McDATA 3000 Manual Do Utilizador

Página de 428
13
Troubleshooting and Diagnostics
 
13-29
UltraNet Edge 3000 Diagnostic Programs
CE1/2 Incr P/B C/U running...
***** PASSED--- CE1/2 Incr P/B C/U                 
passed=1, failed=0
CE1/2 Var Byte C/U running...
***** PASSED--- CE1/2 Var Byte C/U                 
passed=1, failed=0
CE1/2 Var Data C/U running...
***** PASSED--- CE1/2 Var Data C/U                 
passed=1, failed=0
Flash Drive 
Diagnostic Program 
(ISBT)
The UltraNet Edge 3000 Flash Drive diagnostic program resides on 
the UltraNet Edge 3000’s flash drive as the file isbt.dll. Using the 
PROM interface, the file must be loaded into memory and executed 
from there. Upon execution, the following question is prompted to 
the user: Read IDE Flash Disk Configuration (Y/n), type y for yes. 
This program tests the UltraNet Edge 3000’s Flash Drive module and 
verifies that it can perform memory transfer functions to the local 
memory and the buffer memory. 
Individual tests can be selected from the menu or the 99. Execute All 
option can be used to run tests 3, 4, and 5.
Read IDE Flash Disk Configuration Info(Y/n)? y
Reading Configuration from Controller.Done
Reading Config Data into Structure(adrs. 
01A39CEC)....Done
*> SB-TM IDE Diagnostic Test Revision 1.1 12/07/2001 <*
MAIN MENU   SanDisk SDCFB-64
Options={ SINGLE  STOP   0 1 }
Parameters={ 70000000  00000000 }
  { 00180000  00380000  C#0000/H#0/S#02  0001 01 01 }
  {  Random }
Tests Run={  } Total Errors={ 0 }
 0. Exit Diagnostic             4. Run Internal Diags
 1. Set Options                 5. Sector Data Write/Read
 2. Set Parameters             77. Debug Utilities
 3. Register Write/Read Test   99. Execute All
-> 99
Register Write/Read Test running...
***** PASSED--- Register Write/Read Test    passed = 1, 
failed = 0
Run Internal Diags running...
***** PASSED--- Run Internal Diags          passed = 1, 
failed = 0
Sector Data Write/Read running...