Nokia 6800 Series Manual Do Utilizador

Página de 151
 Chapter 8: VPD-6830 Programmable Video DA Series
VPD-6830-CLP
70
 6800/7000 Series - Distribution and Routing Products Installation and Operation Manual
VPD-6830-CLP
Configuration
1. Set the input coupling for either AC or DC coupling using jumpers 
J2
 and J3See Figure 8-3 on page 71 for jumper locations.
2. Set the Clamping mode on jumper J1 to either SoftHard or No 
Clamp
See Figure 8-3 on page 71 for jumper location.
3. Adjust the gain over a range of -3 dB to +3 dB using the R5 
multi-turn potentiometer in the base module. 
Turn the potentiometer Clockwise to Increase the gain. See 
Figure 8-4 on page 71.
4. Adjust the equalization using the R6 multi-turn potentiometer in the 
base module. 
Turn the potentiometer clockwise to obtain more equalization. See 
Figure 8-4 on page 71.
5. Make fine adjustments to the high-frequency response using the R21 
Single-Turn potentiometer in the base module. 
The high-frequency response is factory-set/calibrated. 
Readjustment is not recommended without precise test equipment. 
See Figure 8-4 on page 71.
6. Adjust the Hard clip level using the R4 multi-turn potentiometer 
located on the VPD-6830-CLP submodule. See Figure 8-3 
VPD-6830-CLP Configuration”
 on page 71.
7. Adjust the Luminance clip using the R13 multi-turn potentiometer 
located on the card edge of the submodule card. See Figure 8-4 
VPD-6830-CLP Card-Edge View” 
on page 71.