UMN:CLI                                                                                                                                                              User  Manual 
SURPASS hiD 6615 S223/S323 R1.5 
76                                                                         A50010-Y3-C150-2-7619 
SWITCH(bridge)# show port 1 
------------------------------------------------------------------- 
NO     TYPE     PVID    STATUS        MODE       FLOWCTRL  INSTALLED 
                     (ADMIN/OPER) 
------------------------------------------------------------------- 
 1:  Ethernet      1     Up/Up  Force/Half/100     Off       Y 
SWITCH(bridge)# port speed 1 10 
SWITCH(bridge)# show port 1 
------------------------------------------------------------------- 
NO     TYPE     PVID    STATUS        MODE       FLOWCTRL  INSTALLED 
                     (ADMIN/OPER) 
------------------------------------------------------------------- 
 1:  Ethernet      1     Up/Up  Force/Half/10     Off       Y  
SWITCH(bridge)# 
 
5.2.4 Duplex 
Mode 
Only unidirectional communication is practicable on half duplex mode, and bidirectional 
communication is practicable on full duplex mode. By transmitting packet for two ways, 
Ethernet bandwidth is enlarged two times- 10Mbps to 20Mbps, 100Mbps to 200Mbps. 
To set duplex mode, use the following command. 
Command Mode 
Description 
port duplex
 PORTS {full | half} Bridge 
Sets full or half duplex mode of specified port, enter the 
port number. 
 
The following is an example of configuring duplex mode of port 1 as half mode and show-
ing it. 
SWITCH(bridge)# show port 
------------------------------------------------------------------- 
NO     TYPE     PVID    STATUS        MODE       FLOWCTRL  INSTALLED 
                     (ADMIN/OPER) 
------------------------------------------------------------------- 
 1:  Ethernet      1     Up/Up   Force/Full/100    Off       Y 
SWITCH(bridge)# port duplex 1 half 
SWITCH(bridge)# show port 
------------------------------------------------------------------- 
NO     TYPE     PVID    STATUS        MODE       FLOWCTRL  INSTALLED 
                     (ADMIN/OPER) 
------------------------------------------------------------------- 
 1:  Ethernet      1     Up/Down   Force/Half/100     Off       Y 
SWITCH(bridge)# 
 
5.2.5 Flow 
Control 
Ethernet ports on the switches use flow control to restrain the transmission of packets to 
the port for a period time. Typically, if the receive buffer becomes full, the port transmits a 
pause packet that tells remote ports to delay sending more packets for a specified period 
time. In addition, the Ethernet ports can receive and act upon pause packets from other 
devices.