Emerson Network Router Manual Do Utilizador

Página de 110
12
ProLink
®
 II Software for Micro Motion
®
 Transmitters
Installation and Setup
WARNING
On Model 3350/3700 transmitters, opening the wiring compartment in 
explosive atmospheres can cause an explosion.
Do not remove the compartment covers in an explosive atmosphere within three 
minutes after power is disconnected.
WARNING
On Model 2400S transmitters, removing the transmitter housing cover in a 
hazardous area can cause an explosion.
Because the housing cover must be removed to connect to this transmitter using 
the service port clips or HART clips, these connections should be used only for 
temporary connections, for example, for configuration or troubleshooting purposes.
When the transmitter is in an explosive atmosphere, use a different method to 
connect to your transmitter.
WARNING
Removing the core processor lid can expose the operator to electric shock.
To avoid the risk of electric shock, do not touch the power supply wires or terminals 
while removing or replacing the core processor lid, or while using the RS-485 
terminals.
CAUTION
Connecting a HART device to the transmitter’s primary mA output could 
cause transmitter output error.
If the primary mA output is being used for flow control, connecting the VIATOR 
HART Interface to the output loop, via either the mA terminals or the HART clips, 
could cause the transmitter’s 4–20 mA output to change, which would affect flow 
control devices.
Set control devices for manual operation before connecting the VIATOR HART 
Interface to the transmitter’s primary mA output loop.