TANDBERG D13202 Manual Do Utilizador

Página de 32
TANDBERG GW 
Dataport Command Interface User Guide
 
D13202 Rev 01 
2.2. 
Configuring The Dataport From The Web Interface 
Click on System Configuration tab and then the Dataport button. The Dataport can be 
configured by setting baudrate, parity, databits and stopbits. 
2.3. 
Troubleshooting
 
If communication cannot be established between the PC/terminal and the TANDBERG GW’s 
Dataport the following should be checked: 
  Verify that the serial cable is a straight through 9-pin to 9-pin cable  
  Confirm that the configuration of the PC/terminal’s serial RS-232 port is identical to 
the configuration of the TANDBERG GW RS-232 port. 
  Verify that the PC/terminal’s serial RS-232 port is working properly by connecting it 
back-to-back to another PC/terminal and send characters in both directions
1
                                                           
1
 It requires a null-modem cable to perform this test