TANDBERG D13202 Manual Do Utilizador

Página de 32
TANDBERG GW 
Dataport Command Interface User Guide
 
D13202 Rev 01 
case where the user is trying to transfer a call from an inactive GW port (the user input is 
shown in bold). 
calltransfer 1 999999
*R Invalid gateway id
ERROR
Parameter Setting Commands are commands that set a system parameter to a specific value. 
E.g.: The command ippassword sets the valid password needed to establish an IP connection 
with the GW to a specific value. 
If the command is syntactically correct the GW returns OK, otherwise the GW returns 
ERROR. If *P parameter feedback is activated (ref. command feedback), and the parameter 
is successfully changed, the GW will return the command with the new value. An example of 
*P parameter feedback is shown below (the user input is shown in bold). 
pardial on
OK
*P pardial on
When issuing a Parameter Setting Command with no parameter, the GW will return the 
command with the current setting. E.g.: 
pardial
*P pardial on
OK
Status Commands are commands that list different sets of system parameters. If *S status 
feedback
 is activated (ref. command feedback), status commands are automatically called 
when corresponding parameters are being changed. 
4.2. The 
commands 
The commands are divided into five groups: System Configuration Commands, General GW 
Commands, System Status Commands, Debug Commands and Special Commands.