DXP DVI Pro and DXP HDMI Series • SIS Configuration and Control
51
Switcher Error Responses
When the DXP receives an SIS command and determines that it is valid, it performs the 
command and sends a response to the host device. If the switcher is unable to perform 
the command because the command is invalid or contains invalid parameters, the switcher 
returns an error response to the host. The error response codes are:
E01
 — Invalid input channel number (out of range) 
E10
 — Invalid command 
E11
 — Invalid preset number 
E12
 — Invalid output number or port number 
E13
 — Invalid parameter (out of range) 
E14
 — Command not available for matrix configuration 
E17
 — System timed out (caused by direct write of global presets) 
E21
 — Invalid room number 
E22
 — Busy 
E24
 — Privilege violation (Ethernet and Extron software only) 
E25
 — Device not present 
E26
 — Maximum number of connections exceeded 
E27
 — Invalid event number 
E28
 — Bad filename or file not found 
E30
 — Hardware failure (followed by a colon [:] and a descriptor number) 
E31
 — Attempt to break port pass-through when it has not been set
NOTE:  User privileges extend to all view and read commands except reading the 
administrator password. Users can also perform the following functions:
 
  Creating ties 
  Recalling presets 
  Muting outputs
Using the Command and Response Tables for SIS Commands
 begin on page 55. Upper- and lowercase letters 
are acceptable in the command field except where indicated. The table below shows the 
hexadecimal equivalent of each ASCII character used in the command/response table.
ASCII to Hex Conversion Table
Space
Figure 69. 
ASCII to Hexadecimal Conversion
Special Characters
Use of the following characters is not recommended as part of preset names, the switcher 
name, passwords, or locally created file names:
+ ~ , @ = `
 
[] {} < > ‘’ “” ; (semicolon) : (colon)
 
|
 
\ ? and {space}.