Avaya CMC1 Manual Do Utilizador

Página de 370
CAMA/E911 Installation
Issue 10 June 2005
119
 
Figure 47: CAMA Trunk Group form (page 1)
2. On the Trunk Group screen (page 1), in the 
Group Type:
 field, enter cama.
3. In the 
Group Name:
 field, enter the desired name. 
4. In the 
TAC:
 field, enter the desired trunk access code. 
5. In the 
Outgoing Display:
 field, enter y.
6. In the 
CESID I Digits Sent:
 field, enter the number directed by the Central Office (CO) 
or the Public Safety Answering Point (PSAP).
7. Scroll to page 3 of the form.
Figure 48: Administrable Timers form (page 3)
8. On the Administrable Timers screen (page 3), you may need to adjust these fields 
according to your CO. Scroll to page 5.
 
Page 1 of 11
TRUNK GROUP
Group Number: 1                  Group Type: cama      CDR Reports: y
  Group Name:  cama Trunk Group - E911  COR: 1     TN: 1       TAC: 701
   Direction: outgoing     Outgoing Display? y CESID I Digits Sent: 0
                             Busy Threshold: 99
TRUNK PARAMETERS
         Trunk Type: wink-start
 Outgoing Dial Type: r1mf
  Trunk Termination: rc
 
                                                                     Page 3 of 11
                              TRUNK GROUP
ADMINISTRABLE TIMERS
                                       Outgoing Disconnect (msec): 400
                                  Cama Outgoing Dial Guard (msec): 75
                                      Outgoing Glare Guard (msec): 1000
                                      Cama Wink Start Time (msec): 5000
 Outgoing End of Dial (sec): 1    Outgoing Seizure Response (sec): 4
                                    Disconnect Signal Error (sec): 30